PA6 / PA66 compounds

GL40016X

Prefix GL
General purpose (single resin, unfilled, non-flame-retardant)
Series 40
PA6
Filler 0
Unfilled
MVR 16
160 · 275 °C / 5 kg
Property X
Flow class ×10 (unfilled, flow value ≥ 100; the two digits × 10 give the flow value)

General-purpose PA6 (unfilled)

  1. Planned grade
  2. Available
  3. GREENPOLYMER TDS
  • 60 °CHDT · 1.80 MPa
  • 160 cm³/10 minMelt volume-flow rate (MVR) · 275 °C / 5 kg

Datasheet

Each value is shown with its test standard and conditions.

  • DensityISO 11831.13g/cm³
  • Melt volume-flow rate (MVR)ISO 1133 · 275 °C / 5 kg160cm³/10 min
  • Tensile modulusISO 527-1/-2 · dry3.1GPa
  • Tensile stress at yieldISO 527-1/-2 · dry80MPa
  • Yield strainISO 527-1/-2 · dry3.8%
  • Elongation at breakISO 527-1/-2 · dry24%
  • Charpy notched impact strengthISO 179-1/1eA · 23 °C5.5kJ/m²
  • Heat deflection temperatureISO 75-1/-2 · 1.80 MPa60°C
  • Heat deflection temperatureISO 75-1/-2 · 0.45 MPa180°C
  • Melting temperatureISO 11357-1/-3220°C
  • Comparative tracking indexIEC 60112 · solution A600V
  • Moisture absorptionISO 62 · 23 °C / 50 % RH equilibrium2.6–3.4%

Typical values; not for use as specifications.

Processing window

  • Mold temperature40–60 °C
  • Melt temperature250–270 °C
  • 0.75 % (in flow and across flow, ISO 294-4)Molding shrinkage

Colors

Colors

Natural and black; other colors matched to customer color standards

Description

Unfilled injection-molding PA6 with good flow and toughness, easy to mold. Non-flame-retardant.

Key points

  • Good flow, easy molding
  • Good toughness
  • Oil and wear resistance

Used for

  • Cable ties
  • Connectors
  • Small structural parts for appliances and tools