Servers, telecom and security equipment

Plastic material selection

All materials · 10 grades

Pain points and material advice

  • Drive caddy, hot-swap handle

    Flame retardancy in thin walls

    Pain point
    Front panels and drive trays have many vents and thin walls. Thin-wall parts reach V-0 less easily, and still need good appearance and flow.
    Advice · Candidates
    Advice
    Rate flammability at the actual wall thickness of the thinnest point. For thin-wall parts, choose high-flow flame-retardant grades and confirm filling in mold flow analysis.
  • Air shroud, air baffle

    Continuous operation at high temperature

    Pain point
    Servers and network equipment run around the clock. AI servers draw more power, so areas around fans, air shrouds and power supplies get hotter. Plastic parts creep and warp, and flame retardancy must hold over the long term.
    Advice · Candidates
    Advice
    Choose materials by the actual operating temperature, with reference to the material's relative thermal index (RTI, UL 746B). For large parts such as air shrouds, choose dimensionally stable, low-density materials. For fan frames, choose low-warpage reinforced materials.
    Candidates

    Parts and materials of the rack server

    Pain points and material advice

    • Halogen-free and PTFE-free

      Pain point
      More and more purchasing specifications require halogen-free and low smoke. Some customers are concerned about PFAS and require no PTFE anti-drip agent.
      Advice
      First confirm the definition and limits of "halogen-free" in your specification (such as the chlorine and bromine limits of IEC 61249-2-21). When PTFE must be excluded, choose silicone-based flame-retardant grades and validate flammability and long-term performance.
    • Outdoor equipment: weathering, light and IR transmission

      Pain point
      Outdoor cameras and base stations face sun and rain for years, and housings fade and become brittle. Domes yellow and degrade images. IR illumination windows must look black and let infrared through.
      Advice
      Use weather-resistant grades for housings and test impact and color difference after xenon-arc weathering. Use transparent PC with a hard or UV-resistant coating for domes. Use IR-transmissive black PC for IR windows, setting the wavelength and transmittance targets first.
      Candidates
      • GRN-PCAS-W310
      • GRN-ASA-W110
      • GRN-PC-L110
      • These three grades are HB, so for security-equipment housings flammability must be verified against GB 16796
      • IR-transmissive black PC is available for sensor and LiDAR windows
    • Supply stability and consistency

      Pain point
      Equipment makers need stable, substitutable material sources. Flammability, color and flow must be consistent from batch to batch.
      Advice
      Validate substitute materials fully against the system maker's specification, including flammability, dimensions, color and long-term performance. For volume supply, agree outgoing inspection items for key properties.
      Candidates
      • Chosen per part
      • GREENPOLYMER can provide comparative test data (in-house testing) against your specification

    Plastic parts for servers and storage, network and telecom equipment (switches, routers, Wi-Fi, outdoor base stations, optical networking) and security equipment (cameras, recorders): bezels, drive caddies, fan frames and shrouds, air baffles, connectors and DIMM sockets, PSU housings, camera housings and domes, NVR enclosures, optical-module parts and cable management.

    1. 01 / 07Drive caddies · Drive caddy, hot-swap handle

      GRN-PC-N510

      Halogen-free flame-retardant PC

      Repeated plugging and unplugging; snap fits and spring tabs must be tough; dimensional accuracy

      Tensile strength
      60–68 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    2. 02 / 07Air shroud · Air shroud, air baffle

      GRN-PPE-N510

      Halogen-free flame-retardant mPPE

      Large, thin-wall parts; guide airflow; close to CPUs and GPUs, at high temperatures

      Tensile strength
      50–65 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    3. 03 / 07Cable-management arm · Cable management

      GRN-PA66-E510

      Halogen-free flame-retardant glass-fiber-reinforced PA66

      Repeated bending; snap fits; flame retardancy inside the cabinet

      Tensile strength
      140–170 MPaISO 527-1/-2 · dry
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    4. 04 / 07Power-supply housings · PSU housing

      GRN-PC-N510

      Halogen-free flame-retardant PC

      High-voltage circuits inside, high heat output

      Tensile strength
      60–68 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    5. 05 / 07Fan frames and blades · Fan frame, fan blades

      GRN-PBT-E510

      Flame-retardant glass-fiber-reinforced PBT (high CTI)

      Long-term high speed; motor heat; circuits inside the fan frame

      Tensile strength
      100–130 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    6. 06 / 07Front bezel · Server bezel, front panel

      GRN-PCA-N510

      Halogen-free flame-retardant PC/ABS

      Appearance part; many vents, thin walls; close to live equipment

      Tensile strength
      55–65 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    7. 07 / 07DIMM and PCIe sockets · Connectors

      GRN-PBT-E510

      Flame-retardant glass-fiber-reinforced PBT (high CTI)

      Reflow soldering heat resistance; fine pitch; mating cycle life

      Tensile strength
      100–130 MPaISO 527-1/-2
      Flammability rating
      V-0UL 94 · 1.5 mm; design target, subject to test report

      Typical values

      Material card

    Materials in the rack server

    Example grade / typical values — to be corrected by GREENPOLYMER Typical values. Refer to the actual TDS.

    • GRN-PCA-N510

      Halogen-free flame-retardant PC/ABS

      Tensile strengthISO 527-1/-2
      55–65 MPa
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      V-0
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      10–30 kJ/m²
      MoreLess

      Features

      Halogen-free, thin-wall, dimensionally stable

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      80–95 °C
      DensityISO 1183
      1.17–1.20 g/cm³

      Processing

      Drying
      100–110 °C, 3–4 h
      Melt temperature
      250–280 °C
      Mold temperature
      60–90 °C

      Why this material

      • Appearance part; many vents, thin walls; close to live equipment
    • GRN-PC-N510

      Halogen-free flame-retardant PC

      Tensile strengthISO 527-1/-2
      60–68 MPa
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      V-0
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      20–50 kJ/m²
      MoreLess

      Features

      Tough, dimensionally accurate, heat-resistant

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      115–128 °C
      DensityISO 1183
      1.20–1.24 g/cm³

      Processing

      Drying
      120 °C, 3–4 h; moisture content ≤ 0.02 % recommended
      Melt temperature
      280–310 °C; for flame-retardant grades keep within the TDS upper limit
      Mold temperature
      80–110 °C

      Why this material

      • Drive caddy, hot-swap handleRepeated plugging and unplugging; snap fits and spring tabs must be tough; dimensional accuracy
      • Fan frame, fan bladesLong-term high speed; motor heat; circuits inside the fan frame
      • PSU housing, internal insulating bracketsHigh-voltage circuits inside, high heat output
    • GRN-PBT-E510

      Flame-retardant glass-fiber-reinforced PBT (high CTI)

      Tensile strengthISO 527-1/-2
      100–130 MPa
      Comparative tracking index (CTI)IEC 60112 · design target
      ≥ 600 V
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      V-0
      MoreLess

      Features

      Heat-resistant, creep-resistant, low warpage

      Typical values

      Flexural modulusISO 178
      8–10 GPa
      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      200–215 °C
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      6–10 kJ/m²
      DensityISO 1183
      1.55–1.70 g/cm³

      Processing

      Drying
      120 °C, 3–4 h (desiccant dryer); moisture content ≤ 0.02 %
      Melt temperature
      240–270 °C
      Mold temperature
      60–90 °C; upper end when surface and dimensional stability matter

      Why this material

      • Fan frame, fan bladesLong-term high speed; motor heat; circuits inside the fan frame
      • Connectors, DIMM and PCIe socketsReflow soldering heat resistance; fine pitch; mating cycle life
    • GRN-PPE-N510

      Halogen-free flame-retardant mPPE

      Tensile strengthISO 527-1/-2
      50–65 MPa
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      V-0
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      8–15 kJ/m²
      MoreLess

      Features

      Light, heat-resistant, dimensionally stable

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      90–120 °C
      DensityISO 1183
      1.06–1.12 g/cm³

      Processing

      Drying
      100–110 °C, 2–4 h
      Melt temperature
      260–300 °C
      Mold temperature
      70–100 °C

      Why this material

      • Large, thin-wall parts; guide airflow; close to CPUs and GPUs, at high temperatures
    • GRN-PA66-E510

      Halogen-free flame-retardant glass-fiber-reinforced PA66

      Tensile strengthISO 527-1/-2 · dry
      140–170 MPa
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      V-0
      Flexural modulusISO 178
      8–10 GPa
      MoreLess

      Features

      Tough, stiff, halogen-free flame-retardant

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      230–250 °C
      Charpy notched impact strengthISO 179-1/1eA · 23 °C; dry
      8–12 kJ/m²
      DensityISO 1183
      1.45–1.55 g/cm³

      Processing

      Drying
      80 °C, 4–6 h (desiccant dryer); moisture content 0.05–0.2 % recommended
      Melt temperature
      280–300 °C; do not exceed the TDS upper limit for flame-retardant grades
      Mold temperature
      80–110 °C

      Why this material

      • Repeated bending; snap fits; flame retardancy inside the cabinet
    • GRN-POM-G110

      General-purpose copolymer POM

      Tensile strengthISO 527-1/-2
      60–68 MPa
      Flexural modulusISO 178
      2.4–2.9 GPa
      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      90–105 °C
      MoreLess

      Features

      Wear-resistant, dimensionally stable

      Typical values

      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      5–8 kJ/m²
      DensityISO 1183
      1.39–1.42 g/cm³
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      HB

      Processing

      Drying
      Usually not needed; if damp, 80 °C, 2–3 h
      Melt temperature
      190–210 °C; do not exceed 230 °C
      Mold temperature
      60–90 °C; upper end for precision parts, for more stable dimensions

      Why this material

      • Repeated bending; snap fits; flame retardancy inside the cabinet
    • GRN-PCAS-W310

      Weather-resistant PC/ASA

      Tensile strengthISO 527-1/-2
      50–60 MPa
      Weathering (color difference)ISO 4892-2 · Xenon-arc 1000 h; design target
      ΔE ≤ 3
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      30–50 kJ/m²
      MoreLess

      Features

      Weather-resistant, impact-resistant, tough at low temperature

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      95–110 °C
      DensityISO 1183
      1.14–1.17 g/cm³
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      HB

      Processing

      Drying
      80–85 °C, 2–4 h
      Melt temperature
      230–260 °C
      Mold temperature
      50–80 °C

      Why this material

      • Outdoor sun and rain; impact resistance
    • GRN-PC-L110

      Transparent PC

      Tensile strengthISO 527-1/-2
      60–68 MPa
      Light transmittanceISO 13468-1 · 3 mm; design target
      ≥ 88 %
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      60–80 kJ/m²
      MoreLess

      Features

      High light transmission, impact-resistant

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      125–135 °C
      DensityISO 1183
      1.19–1.21 g/cm³
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      HB

      Processing

      Drying
      120 °C, 3–4 h; moisture content ≤ 0.02 % recommended
      Melt temperature
      280–310 °C; for flame-retardant grades keep within the TDS upper limit
      Mold temperature
      80–110 °C

      Why this material

      • High light transmission; impact resistance (vandal-resistant domes); resistance to UV yellowing
    • GRN-PC-L120

      IR-transmissive black PC

      Tensile strengthISO 527-1/-2
      60–68 MPa
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      60–80 kJ/m²
      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      125–135 °C
      MoreLess

      Features

      Black, IR-transmissive

      Typical values

      DensityISO 1183
      1.19–1.21 g/cm³
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      HB

      Processing

      Drying
      120 °C, 3–4 h; moisture content ≤ 0.02 % recommended
      Melt temperature
      280–310 °C; for flame-retardant grades keep within the TDS upper limit
      Mold temperature
      80–110 °C

      Why this material

      • Black in appearance, lets infrared light through
    • GRN-ASA-W110

      Weather-resistant ASA

      Tensile strengthISO 527-1/-2
      40–50 MPa
      Weathering (color difference)ISO 4892-2 · Xenon-arc 1000 h; design target
      ΔE ≤ 3
      Charpy notched impact strengthISO 179-1/1eA · 23 °C
      8–15 kJ/m²
      MoreLess

      Features

      Weather-resistant, impact-resistant, tough at low temperature

      Typical values

      Heat deflection temperatureISO 75-1/-2 · 1.80 MPa
      85–95 °C
      DensityISO 1183
      1.06–1.08 g/cm³
      Flammability ratingUL 94 · 1.5 mm; design target, subject to test report
      HB

      Processing

      Drying
      80–85 °C, 2–4 h
      Melt temperature
      230–260 °C
      Mold temperature
      50–80 °C

      Why this material

      • Outdoor sun and rain; impact resistance

    Industry overview and trends

    • The server market is growing fast

      In 2025, about 4.727 million servers were sold in China, up about 15 % on the previous year; sales were about RMB 466.3 billion, up about 55 %. AI servers accounted for about 761,000 units and about RMB 253 billion in sales, more than half the total.

    • Rising power density, higher cooling demands

      AI servers draw far more power than general-purpose servers. Fans, air shrouds and power supplies run hotter. Liquid cooling is a key direction for the industry, and plastic parts around cold plates, quick connectors and piping must resist water and coolant and be dimensionally stable.

    • Localized supply chains

      The domestic share of CPUs, AI chips, controller chips and power supplies is rising. System makers need stable, substitutable material supply and flame-retardant materials with consistent batches.

    • More outdoor communications and security equipment

      Outdoor base stations, Wi-Fi equipment and cameras face sun and rain for years. Housings must be weather and impact resistant, and some parts must also be light-transmitting, IR-transmissive or RF-transparent.

    • More environmental purchasing requirements

      More and more purchasing specifications require halogen-free, low-smoke materials. The EU universal PFAS restriction is still a proposal, but some customers already ask for grades without PTFE anti-drip agents.

    • In 2025, about 4.727 million servers were sold in China (about +15 %), worth about RMB 466.3 billion (about +55 %). About 761,000 were AI servers, worth about RMB 253 billion, more than half of the total.
    • AI servers use much more power. Fans, air baffles and PSUs run hotter. Liquid cooling is a key direction; plastic parts near cold plates, quick connectors and pipes must resist water and coolant.
    • Supply chains are localizing. OEMs need stable, second-source materials with consistent flame-retardant performance.
    • Outdoor base stations, Wi-Fi units and cameras need weathering, impact resistance, and in some parts light, IR or RF transmission.
    • More specifications ask for halogen-free materials.

    Part-to-material guide

    Full list · 14 parts

    This table shows common industry practice for first-round selection. The final choice depends on the applicable standards, the OEM's material specification and validation results (to be verified by GREENPOLYMER).

    Server bezel, front panel

    Typical materials: Flame-retardant PC/ABS, flame-retardant PC
    Why

    Appearance part; many vents, thin walls; close to live equipment

    Key requirements

    V-0 or V-1 (per system requirements); appearance; dimensional stability; halogen-free

    Common standards

    IEC 62368-1; UL 94

    GREENPOLYMER grade

    GRN-PCA-N510; GRN-PCA-N520 (thin wall, high flow); GRN-PCA-S520 (halogen-free, without PTFE anti-drip agent)

    Example grade / typical values — to be corrected by GREENPOLYMER

    Drive caddy, hot-swap handle

    Typical materials: Flame-retardant PC, flame-retardant PC/ABS, PC-GF
    Why

    Repeated plugging and unplugging; snap fits and spring tabs must be tough; dimensional accuracy

    Key requirements

    V-0; toughness; snap-fit fatigue; dimensional accuracy

    Common standards

    UL 94; IEC 62368-1

    Example grade / typical values — to be corrected by GREENPOLYMER

    Fan frame, fan blades

    Typical materials: Flame-retardant PBT-GF, flame-retardant PA66-GF, flame-retardant PC (small fans)
    Why

    Long-term high speed; motor heat; circuits inside the fan frame

    Key requirements

    V-0; heat resistance; creep resistance; dimensional stability; low warpage

    Common standards

    UL 94; UL 507 (fans, product level); IEC 62368-1

    GREENPOLYMER grade

    GRN-PBT-E510; GRN-PA66-E510 (halogen-free flame retardant); GRN-PC-N510

    Example grade / typical values — to be corrected by GREENPOLYMER

    Air shroud, air baffle

    Typical materials: Flame-retardant PC sheet or molding, flame-retardant mPPE (commonly called PPO), flame-retardant PC/ABS
    Why

    Large, thin-wall parts; guide airflow; close to CPUs and GPUs, at high temperatures

    Key requirements

    V-0; heat resistance; dimensional stability; light weight

    Common standards

    UL 94; UL 746C; IEC 62368-1

    GREENPOLYMER grade

    GRN-PPE-N510 (mPPE, commonly called PPO); GRN-PC-N510; GRN-PCA-N510

    Example grade / typical values — to be corrected by GREENPOLYMER

    Connectors, DIMM and PCIe sockets

    Typical materials: LCP, PA46, PA9T / PA10T, PBT-GF
    Why

    Reflow soldering heat resistance; fine pitch; mating cycle life

    Key requirements

    Reflow resistance; dimensional accuracy; V-0; comparative tracking index (CTI)

    Common standards

    IEC 60112; UL 94; IPC/JEDEC J-STD-020 (reflow conditions)

    GREENPOLYMER grade

    Standard connectors: GRN-PBT-E510 (high CTI), GRN-PA66-E510. Reflow-resistant LCP / high-temperature nylon: Available as a project-based development

    Example grade / typical values — to be corrected by GREENPOLYMER

    PSU housing, internal insulating brackets

    Typical materials: Flame-retardant PC, flame-retardant PC/ABS, flame-retardant PBT-GF, flame-retardant PA66-GF

    Network equipment housing (switch, router, Wi-Fi)

    Typical materials: Flame-retardant PC/ABS, flame-retardant PC; weather-resistant PC/ASA outdoors
    Why

    RF-transparent (antenna inside the housing); many vents; appearance

    Key requirements

    V-0 or V-1; dielectric properties; appearance; outdoor weather resistance

    Common standards

    IEC 62368-1; UL 746C; IEC 60529

    GREENPOLYMER grade

    GRN-PCA-N510; GRN-PC-N510; outdoor: GRN-PCAS-W310 (HB; flammability must be verified against the applicable standard)

    Example grade / typical values — to be corrected by GREENPOLYMER

    Outdoor camera housing

    Typical materials: Weather-resistant PC, weather-resistant PC/ASA, PC/ABS; aluminum alloy at the high end
    Why

    Outdoor sun and rain; impact resistance

    Key requirements

    UV resistance (UL 746C f1, for outdoor use); IP66 / IP67; impact resistance (IK rating); low-temperature toughness

    Common standards

    UL 746C; IEC 60529; IEC 62262; GB 16796-2022

    GREENPOLYMER grade

    GRN-PCAS-W310; GRN-ASA-W110; GRN-PCA-W310 (all HB; flammability must be verified against GB 16796)

    Example grade / typical values — to be corrected by GREENPOLYMER

    Camera dome, lens window

    Typical materials: Transparent PC (with hard or anti-fog coating), PMMA
    Why

    High light transmission; impact resistance (vandal-resistant domes); resistance to UV yellowing

    Key requirements

    Light transmittance; haze; IK rating; UV resistance

    Common standards

    ISO 13468; ISO 14782; IEC 62262; GB 16796-2022

    GREENPOLYMER grade

    GRN-PC-L110 (transparent PC; HB; flammability must be verified against GB 16796)

    Example grade / typical values — to be corrected by GREENPOLYMER

    IR illuminator window, sensor window

    Typical materials: IR-transmissive black PC, PMMA
    Why

    Black in appearance, lets infrared light through

    Key requirements

    IR transmittance (design target); visible light blocking; UV resistance

    Common standards

    Optical performance per customer specification

    GREENPOLYMER grade

    IR-transmissive black PC is available for sensor and LiDAR windows. Grade provided per project

    NVR / DVR enclosure, front panel

    Typical materials: Flame-retardant PC/ABS, flame-retardant ABS, metal chassis + plastic panels

    Optical-module pull tab, housing parts, fiber connectors

    Typical materials: PC, PBT, PEI, LCP (precision parts)
    Why

    Small, high-precision parts; plugging and unplugging

    Key requirements

    Dimensional accuracy; heat resistance; mating cycle life; color coding

    Common standards

    IEC 61754 (fiber optic connector interfaces); UL 94

    GREENPOLYMER grade

    Pull tabs and plastic housing parts: GRN-PC-N510, GRN-PBT-E510. PEI / LCP precision parts: Available as a project-based development

    Example grade / typical values — to be corrected by GREENPOLYMER

    Cable management, cable arm, tie mounts

    Typical materials: PA66, flame-retardant PC/ABS, PP
    Why

    Repeated bending; snap fits; flame retardancy inside the cabinet

    Key requirements

    Toughness; snap-fit fatigue; V-0 or V-2 (as required)

    Common standards

    UL 94; UL 62275 (cable ties, where applicable)

    GREENPOLYMER grade

    GRN-PA66-E510; GRN-PCA-N510; GRN-POM-G110 (snap-fits with no flammability requirement only; HB, flammability must be verified against the applicable standard)

    Example grade / typical values — to be corrected by GREENPOLYMER

    Outdoor base-station radome, outdoor cabinet parts

    Typical materials: Weather-resistant PC/ASA, ASA, glass-fiber-reinforced PBT, glass-fiber-reinforced PP
    Why

    RF-transparent; long-term outdoor use

    Key requirements

    Low dielectric constant and loss; UV resistance (f1); impact resistance; low-temperature toughness

    Common standards

    UL 746C; IEC 60529; dielectric properties per customer specification

    GREENPOLYMER grade

    GRN-PCAS-W310; GRN-ASA-W110 (both HB; flammability must be verified against the applicable standard); GRN-PCAS-W510 (flame-retardant weather-resistant PC/ASA; flammability rating per test report (to be verified by GREENPOLYMER))

    Example grade / typical values — to be corrected by GREENPOLYMER

    Notes

    • IEC 62368-1 (GB 4943.1-2022 for China CCC) sets different flammability requirements for fire enclosures and internal parts; check the specific classes against the standard clause. Confirm the requirement for each part with the equipment design.
    • Plastic parts used outdoors often need UL 746C f1 (property retention after UV and water immersion). UL 746C f1 rating of the weather-resistant grades: to be verified by GREENPOLYMER.
    • Carbon-fiber-reinforced materials block signals; do not use them for radomes or housings with built-in antennas.
    • IEC 62368-1, UL 507, IEC 62262 and similar are product or component standards; what they certify is not the material itself.

    GREENPOLYMER grades for servers, telecom and security equipment

    GradeMaterialRecommended partsDensityTensileHDTFlammability (target)
    GRN-PCA-N510Halogen-free flame-retardant PC/ABSFront panels, network equipment housings, video recorder housings1.17–1.20 g/cm³55–65 MPa80–95 °CV-0 @ 1.5 mm
    GRN-PCA-N520Halogen-free flame-retardant PC/ABS (thin wall, high flow)Thin-wall front panels, vent grilles1.17–1.20 g/cm³55–62 MPa75–88 °CV-0 @ 1.0 mm
    GRN-PCA-S520Silicone-based flame-retardant PC/ABS (without PTFE anti-drip agent)Front panels, housings1.15–1.20 g/cm³50–60 MPa85–100 °CV-0 @ 1.5 mm
    GRN-PC-N510Halogen-free flame-retardant PCDrive trays, power supply housings, air shrouds1.20–1.24 g/cm³60–68 MPa115–128 °CV-0 @ 1.5 mm
    GRN-PC-S520Silicone-based flame-retardant PC (without PTFE anti-drip agent)Drive trays, power supply housings1.19–1.22 g/cm³58–66 MPa118–130 °CV-0 @ 1.5 mm
    GRN-PCA-E510Flame-retardant glass-fiber-reinforced PC/ABSPower supply housings, housing frames1.25–1.35 g/cm³70–95 MPa100–120 °CV-0 @ 1.5 mm
    GRN-PPE-N510Halogen-free flame-retardant mPPE (commonly called PPO)Air shrouds, air ducts1.06–1.12 g/cm³50–65 MPa90–120 °CV-0 @ 1.5 mm
    GRN-PBT-E510Flame-retardant glass-fiber-reinforced PBT (high CTI)Fan frames, connectors, power supply brackets1.55–1.70 g/cm³100–130 MPa200–215 °CV-0 @ 1.5 mm
    GRN-PA66-E510Halogen-free flame-retardant glass-fiber-reinforced PA66Fan frames, connectors, cable management parts1.45–1.55 g/cm³140–170 MPa (dry)230–250 °CV-0 @ 1.5 mm
    GRN-ABS-F510Flame-retardant ABSVideo recorder panels (cost sensitive)1.16–1.20 g/cm³38–45 MPa75–85 °CV-0 @ 1.5 mm
    GRN-PCAS-W310 / GRN-ASA-W110Weather-resistant PC/ASA / weather-resistant ASA (non-flame-retardant)Outdoor camera housings, radomes1.06–1.17 g/cm³40–60 MPa85–110 °CHB @ 1.5 mm (flammability must be verified against GB 16796)
    GRN-PC-L110Transparent PC (non-flame-retardant)Camera domes, lens windows1.19–1.21 g/cm³60–68 MPa125–135 °CHB @ 1.5 mm (flammability must be verified against GB 16796)
    • Typical values. Refer to the actual TDS. The CTI ≥ 600 V of GRN-PBT-E510 is a design target. RTI and UL 746C f1 data are to be verified by GREENPOLYMER.
    • For full properties, see Products. For how to choose, see the selection guide.

    Why GREENPOLYMER

    • Custom compounding

      GREENPOLYMER does flame-retardant, reinforcing, toughening and weather-resistant compounding, with flame retardancy mainly halogen-free. Formulations can be adjusted to the system maker's material specification. Materials marked "Available as a project-based development" in the table can be developed with GREENPOLYMER engineers.

    • Flammability and electrical testing

      In-house testing covers horizontal and vertical burning, glow-wire, needle flame and comparative tracking index (CTI), for screening during development and comparative testing of substitute materials (see "In-house testing" below).

    • Technical support

      Material selection assessment and advice on wall thickness and ribs for thin-wall parts; mold flow analysis can be done together with your tooling team.

    • Halogen-free flame retardancy

      GREENPOLYMER's flame-retardant technology focuses on halogen-free and fluorine-free solutions. Silicone-based flame-retardant grades do not use PTFE anti-drip agents.

    • Color matching

      The Shenzhen Color Matching Center works to RAL and Pantone numbers and customer color plaques.

    • Recycled grades

      Each grade can be customized with recycled content (suffix -R). The recycled share is set per project, with traceability documents. Certificate to be uploaded.

    • Fast sampling

      Free samples of 1–5 kg are available for standard grades, usually shipped in 3–7 working days. Custom formulation samples usually take 1–3 weeks.

    • Sites

      The company headquarters and main plant are in Jiangxi, which is also home to a 3D printing filament industry cluster. GREENPOLYMER also has the Hangzhou Production Base, the Shenzhen Color Matching Center and the Dongguan Development Center. 6,000+ t capacity; 29,000+ m² total plant area.

    • Patents

      8 invention patents.

    • In-house testing

      Test equipment covers melt flow rate, Izod and Charpy impact, horizontal and vertical burning (UL 94 method), heat deflection temperature and Vicat, constant temperature and humidity, UV and xenon-arc weathering, XRF, TGA, DSC, glow-wire, needle flame, comparative tracking index (CTI) and salt spray. In-house tests are for development and quality control and do not replace third-party test reports or UL certification.

    3D printing in ICT and security equipment development

    UseExampleRecommended filament
    Fit checksAssembly of drive trays, air shrouds and cable management partsGRN3D-PETG-S01; GRN3D-PC-E01
    Appearance samplesStyling reviews of front panels and camera housingsGRN3D-PLA-M01 (Matte); GRN3D-PCA-E01 (PC/ABS)
    Outdoor samplesOutdoor camera mounts, radome samplesGRN3D-ASA-S01
    Heat-resistant functional partsAir duct samples, test fixturesGRN3D-PC-E01; GRN3D-PA6-G25
    Small data-center partsBlanking panels, label holders, cable clipsGRN3D-PETG-S01; GRN3D-PETG-C01
    • Printed parts cannot replace injection-molded samples for flammability certification. For parts used inside cabinets, use injection-molded parts of the production grade.
    • The properties of printed parts depend on print orientation, layer thickness and infill. Carbon-fiber-reinforced filament may affect wireless signals.

    For filament details, see the filament overview, Engineering series and Everyday Functional series. To prototype in filament and then injection-mold the same material family, see From compounding to filament. For more 3D printing applications, see the 3D printing industry page.

    Industry FAQ

    Q1. Do all server plastic parts need V-0?

    Not always. IEC 62368-1 sets requirements by energy source and part location. Many OEMs simply require V-0 in their specifications. Follow the equipment design and your specification, and rate at the actual wall thickness.

    Q2. Why is mPPE common for air shrouds?

    mPPE (often called PPO) has low density, good dimensional stability, heat resistance and low water uptake, and halogen-free FR grades reach V-0 easily. These properties reduce warpage in large thin parts. FR PC or PC sheet are also used, depending on design and cost.

    Q3. How do I choose materials for outdoor camera housings?

    Define the conditions first: sunlight, temperature range, IP and IK ratings. Housings often use weather-resistant PC/ASA or ASA, and outdoor plastics often need UL 746C f1. When weather-resistant HB grades are used for security-equipment housings, flammability must be verified against GB 16796. Domes use clear PC with UV or hard coating. IR illuminator windows can use IR-transmissive black PC.

    Q4. Do you offer flame-retardant grades without PTFE?

    Yes. Our silicone-based FR PC and PC/ABS grades use no PTFE anti-drip agent. Confirm your specification first, then validate flammability and long-term performance. The EU universal PFAS restriction is still a proposal.

    Request a quote / sample

    Please tell us:

    • Equipment type (server, network equipment, outdoor base station, camera, video recorder) and part name
    • Flammability requirement, test thickness and working temperature
    • Halogen-free, PTFE-free or other requirements
    • Outdoor use, light or IR transmission requirements
    • Current material and estimated annual volume
    • TDS / SDS: Chinese and English versions are available by email.
    • For samples and the development process, see the FAQ.

    Contact us

    Tell us about the part, material requirements, equipment and expected volume. We will recommend suitable grades and the validation data you need.